Search results for "Biaxial test"

showing 2 items of 2 documents

Identification of circumferential regional heterogeneity of ascending thoracic aneurysmal aorta by biaxial mechanical testing

2019

Abstract Ascending thoracic aortic aneurysm (ATAA) in patients with bicuspid aortic valve (BAV) can present an asymmetrical aortic dilatation compared with patients with tricuspid aortic valve (TAV). This pattern of aneurysm dilatation led us to hypothesize that biomechanical differences likely induced by regional heterogeneity of material properties can underlie the observed asymmetric enlargement discrepancies between BAV ATAA and TAV ATAA. This study aimed to characterize the mechanical properties and associated aortic tissue stiffness changes along the circumferential direction of aortic rings collected from surgically-repaired patients with ATAA. Biaxial material testing was performed …

0301 basic medicineAortic valveMaleMaterial parameterBicuspid aortic valveHeart Valve DiseasesAorta Thoracic030204 cardiovascular system & hematologyThoracic aortic aneurysm03 medical and health sciences0302 clinical medicineBicuspid aortic valveAneurysmVascular StiffnessBicuspid Aortic Valve Diseasemedicine.arteryMedicineHumansIn patientMolecular BiologyAgedAged 80 and overAortaAortic Aneurysm Thoracicbusiness.industryAscending aortic aneurysmSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyMiddle Agedmedicine.diseaseSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Tissue stiffness030104 developmental biologymedicine.anatomical_structureAortic Valvecardiovascular systemFemaleTissue stiffnessCardiology and Cardiovascular MedicinebusinessBiaxial testingSettore ICAR/08 - Scienza Delle CostruzioniElastic fiberDilatation Pathologic
researchProduct

Experimental Characterization of the Human Meniscal Tissue

2018

The meniscus plays a critical role in load transmission, stability and energy dissipation in the knee joint. Loss of the meniscus leads to joint degeneration and osteoarthritis. In a number of cases replacement of the resected meniscal tissue by a synthetic implant might avoid the articular cartilage degeneration. None of the available implants presents optimal biomechanics characteristic due to the fact the biomechanics functionality of the meniscus is not yet fully understood. Mimicking the native biomechanical characteristics of the menisci seems to be the key factor in meniscus replacement functioning. This is extremely challenging due to its complex inhomogeneous microstructure, the la…

Materials sciencemeniscal tissue0206 medical engineeringEnergy Engineering and Power TechnologyArticular cartilage02 engineering and technologyDegeneration (medical)OsteoarthritisKnee JointMeniscus (anatomy)fractional viscoelasticityIndustrial and Manufacturing Engineering0203 mechanical engineeringArtificial IntelligencemedicineInstrumentationMeniscal tissueRenewable Energy Sustainability and the EnvironmentBiomechanicsComputer Science Applications1707 Computer Vision and Pattern Recognitionmusculoskeletal systemmedicine.disease020601 biomedical engineeringCharacterization (materials science)Computer Networks and Communication020303 mechanical engineering & transportsmedicine.anatomical_structureBiaxial testSettore ICAR/08 - Scienza Delle CostruzioniBiomedical engineering2018 IEEE 4th International Forum on Research and Technology for Society and Industry (RTSI)
researchProduct